FIRE ALARM SYSTEMS
Below is the detailed information regarding fire alarm systems...
CONVENTIONAL SYSTEM


Apollo FP Control Panels

  • 2,4,6,8,14,24 & 32 Zone versions
  • Easy to Fit
  • Attractive Styling
  • Easy to Maintain
  • Complies with BS 5839, part 4, 1988

CONTROLS

1. EXTERNAL

Control Buttons enabled by keyswitch

  1. Reset/Resound/Test Zone Lamps
  2. Silence Alarm Sounders
  3. Silence Fault Sounders
  4. Evacuate

2. INTERNAL

  1. Engineer's one man test.
  2. Zone isolate
  3. Revert to 1980 BS ( no resistors in call points)

INDICATORS

1. EXTERNAL

Sounder Fault
Power Supply Fault
Mains On
Zone Fire
Zone Fault

2. INTERNAL

Open Circuit Zone Fault
Short Circuit Zone Fault
Zone Isolated
Engineer Test Selected

 

OUTPUTS

Two sounder circuits. Voltage free change over contacts on Alarm, Auxiliary 24 VDC (may be removed at alarm) - 100mA. Ancillary connections for expansion modules will allow the following.

  1. Repeater Panels
  2. Multiple Sounder Outputs
  3. Fault relays
  4. Connection to Landlords panel
  5. Larger power supply

FIRE DETECTOR SERIES 65


SERIES 65 IONISATION SMOKE DETECTOR

The sensing part of the detector consists of two chambers - an open, outer chamber and a semi-sealed reference chamber within. Mounted in the reference chamber is a low activity radioactive foil of Americium 241 which enables current to flow between the inner and outer chambers when the detector is powered up. As smoke enters the detector, it causes reduction of the current flow in the outer chamber and hence an increase in voltage measured at the junction between the two chambers. The voltage increase is monitored by the electronic circuitry which triggers the detector into the alarm state at a preset threshold. An externally visible LED will light up when the detector changes to alarm state.

SERIES 65 OPTICAL SMOKE DETECTOR

Optical smoke detectors incorporate a pulsing LED located in a labyrinth within the housing of the detector. The labyrinth is designed to exclude light from any external source. At an angle to the LED is a photo-diode which normally does not register the column of light emitted by the LED. In the event of smoke from a fire entering the labyrinth the light pules from the LED will be scattered and hence registered by photo-diode. If the photo diode "sees" smoke on the two following pulses, the detector changes to the alarm state when the indicator LED will light up. The detector housing is identical to that of the ionisation smoke detector. It is distinguished from this type by having an indicator LED which is clear quiescent state but produces red light in alarm.

SERIES 65 HEAT DETECTOR

The series 65 heat detectors are reset table and operate by suing a matched pair of thermistors to sense heat.

SERIES 65A COMBINED HEAT AND SMOKE DETECTOR

Series 65A are the latest type of detectors offering heat and optical smoke detection from the single unit.


MANUAL CALL STATIONS


The design and feature of Models from the new World Series of Call Points benefit from the experience gained during nearly quarter of a century spent specialising in Manual Call Points of the Break Glass Type.

Standard Model for ordinary environment

MCP-100

Model for ordinary environment (press glass)

MCP-100/PG

Model for weather proof environment

MCP-100/WP

Model for hazardous environment

MCP-100/Ex


ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM


The smoke/heat detectors and manual call stations are programmed through the control panel in such a way that each component is given a number and the exact location. Like optical smoke detectors No. 7, location generator room. Which means when the fire is detected by detector No. 7, the control panel will show the detector number and location on its display and a print out by the printer, which makes the fire staff to go exactly at the right place rather to wasting time in searching the whole zone, thus minimising the response time, and we all know, in a fire situation even seconds count. The complete system can be networked by using specially designed software and computers for sophisticated monitoring. Similar faults are also identified by exact location.

Apollo AFP Control Panels

Fully compliant with EN54 Parts 2 & 4 and BS 5839 Part 4. The new AFP loop analogue addressable fire panel offers high performance at a competitive price. Attractively designed, easy to use and simple to install, it's wide range of features include:

  • 126 addressable devices per loop.
  • Easy-to-read 80 character back-lit display
  • Four separate independently programmable sounder circuits rated at a total of 3A.
  • Powerful short circuit protected loop drivers allows the connection of up to 32 loop driven sounders.
  • Evacuate, alert and class change inputs
  • Fire, fault and pre-alarm outputs.
  • 999 event memory.
  • RS232 port provided for connection to external serial printer.
  • Sophisticated test and maintenance facilities.
  • Panel can be programmed on-site via tactile switches on panel front or via an easy to use, low-cost upload/download PC programme.
  • Comprehensive Auto-Learn 'facility allows panel to self configure to devices connected to the loop.
  • Push button entry code access protection.
  • Detailed description of faults on LCD display.

Analogue Addressable Loop Device

XP95 IONISATION SMOKE MONITOR

As smoke enters the outer chamber the flow drops and voltage increases. The voltage is measured and an analogue signal is converted to digital for transmission to control equipment. Pre-alarm or fire alarm is instigated by the microprocessor when smoke density increases to pre-set-levels.

XP95 OPTICAL SMOKE MONITOR

When smoke enters the chamber it scatters light onto the photo-diode, increasing the signal transmitted to control equipment. The clear LED emits red.

XP95 TEMPERATURE MONITOR

The XP95 temperature monitor has a low air-flow resistant case for good contact between sensing thermistor and surrounding air. Temperature is measured by a single themistor network which gives a voltage output proportional to the external air temperature. The signal is processed and transmitted to control equipment.

XP95 MANUAL CALL POINT

When operated the manual call point interrupts the polling cycle and can report its address in under 0.2 seconds.

XP95 ISOLATOR

Designed to protect the XP95 loop from short circuit fault, preventing the whole loop becoming inoperable.

The line resistance of the XP95 isolator is particularly low.


ALARM DEVICES


APOLLO ELECTRONIC SOLENOID BELL

A unique, patented alarm bell designed for use in fire, security, industrial and other signalling systems. The benefits of quality of sound output, with reduced current consumption, are made possible by combining a miniature solenoid with an integrated electronic control circuit.

 

  • Integrated Electronic Control Circuitry
  • Increased Reliability - No Mechanical contacts or Rotary Parts to wear
  • Two in, Two out wiring to comply with BS5839: PART 1 :1998

Dimensions:

6" (155mm) dia. X 3 ½" (85mm) depth

Nominal Voltage :

24 VD.C.

Voltage Range :

18-30V D.C

Nominal Current :

30 mA

Nominal Output :

93-95 dBA at 1 metre

Movement :

Solenoid with electronic control

Syrex Shrieker

The siren shrieker is a low current fire alarm sounder ideally suited for long cable runs where a low current draw is required. Termination in the base allows quick and easy installation.

Type :

Standard

Voltage :

12V/24V DC

Current :

8mA

dB at 1m :

100 + 3dB

Frequency :

700/950 Hz

Tones :

9

Rating :

Continuous

Case :

High impact ABS

SYREX LC

The Syrex LC is a high output low current consumption sounder having 3 different, notes selectable on the same unit : continuous, warble and pip.

High impact flame retardant ABS case. Protection to IP65 available as standard.

Voltage Range :

24 V DC

Current :

20mA

Audibility :

dB at 1m

Syrex Shrieker XN

Voltage Range :

24V DC

Current :

50 mA

Audibility :

100dB at 1m +3dB

Frequency :

70/950 Hz

Flash Energy :

0.5 Joule (1Hz)

Case :

High Impact ABS

Low Current Xenon Beacon

A low cost, low power xenon beacon ideal for fire alarm applications.

 

Voltage Range :

24V DC

Current :

45 mA

Flash Rate :

60 FPM(1hz)

Flash Energy:

0.65 joule (AC version)

1.2 joule (AC version)

Case Material :

Polycarbonate lens and UV stabilised polycarbonate /ABS body & base

KLS 125 Xenon Beacon

Voltage Range :

24V DC

Current :

170 mA

Flash Rate :

70 FPM(1Hz)

Flash Energy :

2.9 Joules

Case Material :

Polycarbonate toughened UV stable dome. ABS base.