The smoke/heat detectors and manual call stations are programmed through the control panel in such a way that each component is given a number and the exact location. Like optical smoke detectors No. 7, location generator room. Which means when the fire is detected by detector No. 7, the control panel will show the detector number and location on its display and a print out by the printer, which makes the fire staff to go exactly at the right place rather to wasting time in searching the whole zone, thus minimising the response time, and we all know, in a fire situation even seconds count. The complete system can be networked by using specially designed software and computers for sophisticated monitoring. Similar faults are also identified by exact location.
Apollo AFP Control Panels
Fully compliant with EN54 Parts 2 & 4 and BS 5839 Part 4. The new AFP loop analogue addressable fire panel offers high performance at a competitive price. Attractively designed, easy to use and simple to install, it's wide range of features include:
- 126 addressable devices per loop.
- Easy-to-read 80 character back-lit display
- Four separate independently programmable sounder circuits rated at a total of 3A.
- Powerful short circuit protected loop drivers allows the connection of up to 32 loop driven sounders.
- Evacuate, alert and class change inputs
- Fire, fault and pre-alarm outputs.
- 999 event memory.
- RS232 port provided for connection to external serial printer.
- Sophisticated test and maintenance facilities.
- Panel can be programmed on-site via tactile switches on panel front or via an easy to use, low-cost upload/download PC programme.
- Comprehensive Auto-Learn 'facility allows panel to self configure to devices connected to the loop.
- Push button entry code access protection.
- Detailed description of faults on LCD display.
Analogue Addressable Loop Device
XP95 IONISATION SMOKE MONITOR
As smoke enters the outer chamber the flow drops and voltage increases. The voltage is measured and an analogue signal is converted to digital for transmission to control equipment. Pre-alarm or fire alarm is instigated by the microprocessor when smoke density increases to pre-set-levels.
XP95 OPTICAL SMOKE MONITOR
When smoke enters the chamber it scatters light onto the photo-diode, increasing the signal transmitted to control equipment. The clear LED emits red.
XP95 TEMPERATURE MONITOR
The XP95 temperature monitor has a low air-flow resistant case for good contact between sensing thermistor and surrounding air. Temperature is measured by a single themistor network which gives a voltage output proportional to the external air temperature. The signal is processed and transmitted to control equipment.
XP95 MANUAL CALL POINT
When operated the manual call point interrupts the polling cycle and can report its address in under 0.2 seconds.
XP95 ISOLATOR
Designed to protect the XP95 loop from short circuit fault, preventing the whole loop becoming inoperable.
The line resistance of the XP95 isolator is particularly low.
|