| Trolly Mounted Fire Extinguisher |
|
|
| Dry Powder |
|
 INTRODUCTION
Dry Chemical Powder is one of the latest fire extinguishing agent and can effectively control all types of fires, may be on ordinary combustible materials (Wood, cloth, paper), highly inflammable liquids (oil, petrol, kerosene), gases expelled under pressure (Acetylene, Propane) and/or fires under electric tension. The trolly-mounted extinguishers can easily be carried from one place to another and, due to large contents, are more dependable.
TECHNICAL DATA
Model |
DC-SP-50 |
DC-50 |
DC-100 |
Contents |
50 Kg (110 lbs) Dry Chemical Powder |
50 Kg Dry Chemical Powder |
100 Kg Dry Chemical Powder |
Pressurizing
Gas |
Nitrogen
Stored Pressure |
Co 2 in External Cartridge |
Construction |
Main barrel of 10 Swg. M.S. Shet, Welded, tested to 25 Kg/ Cm 2 (350 lbs/sq inch). |
Max. Range |
8-12 meters (25-36 ft) |
8-12 meters (25-36 ft) |
Discharge |
30-50 Seconds |
30-50 seconds |
60-100 seconds |
Attachments |
6 meters (20 ft) of high pressure 3/4O (18 mm) dia hose, on-off control and discharge nozzle. |
Trolley |
2-wheeled, with rubber tyres |
Paint |
Red/Blue |
Label |
Non-damaging, with instructions for operation |
|
|
| CO2 CARBON DIOXIDE |
|
SUITABLE FOR: Fires on Electrical Equipment, Wireless Installations, Computers, Generators, Transformers, Electric Circuits, Panels and Electric Motors Etc.
RECOMMENDED FOR: Radio Stations, High Power Transmitters, Power Houses, Electric Sub-Stations, Refineries, Oil Depots, Airports, Engine Sheds and Industrial Complexes.
TECHNICAL DETAILS
Model |
|
CO 2 - 14 |
CO 2 - 25 |
CO 2 - 50 |
CO2 |
Kgs Lbs. |
14
30 |
25
55 |
50
110 |
Discharge Time |
Sec. |
30-40 |
35-45 |
60-85 |
Stream Range |
Meters |
5-6 |
6-7 |
7-8 |
Hose Length |
Meters |
1 |
5 |
6 |
No. of Cylinders |
|
2 x 7 kg |
1 X 25 kg |
2 x 25 kg |
- Cylinders are imported while trollies and other accessories are fabricated by us.
- Cylinders are painted in red while chassis is coloured black.
Operation
The cylinder contains carbon dioxide which is released by opening the control wheel and discharged to the scene of fire through flexible hose and horn. The discharge can be interrupted by closing the wheel.
|
|
| WATER TYPE FIRE EXTINGUISER |
|
INTRODUCTION
Inspite of all the achievements in fire technology, water is still accepted as the cheapest and most effective fire fighting agent. For this purpose usually Fire Hydrant System is installed in big industries, ware houses and buildings. This System assures the availability of water in large quantity.
In areas where it is not possible for install the System due to unavailability of resources of cost, Water Type Fire Extinguishers are the best alternate.
SPECIFICATIONS
Model |
W-150 |
W-Sp-45 |
Extinguishing material |
150-litres (34-gallons) of plain water, in main Cylinder. |
45-litres (10-gallons) of plain water, in main Cylinder. |
Construction |
Main Cylinder of 10 gauge M.S. sheet, welded |
|
Pressurising Agent |
CO2 gas in a Cartridge fitted on the external side of main body. |
Nitrogen Stored Procedure. |
Duration of Discharge |
120-180 Seconds |
30-50 Seconds |
Operating Pressure |
7 Kg/cm2 (nominal) Approx. |
|
Range of Jet |
15-20 meters (50-70 feet) |
10-15 meters (35-50 ft.) |
Wheels |
2 rubber wheels of 400 mm (16") dia |
2 rubber wheel of 225 mm ( 9") dia |
Attachments |
- 25 mm x 7.5m (1" x 25 ft) high pressure rubber hose.
- One on-off valve with hand control
- One Nozzle.
|
- 18 mm x 3m (¾" x 10 ft) high pressure rubber hose.
- One on-off valve with hand control.
- One nozzle.
|
Finish |
Fire bridage red |
Fire bridage red/ |
|
|
|
Label |
Non damaging with instructions for operation. |
|
|
|
| AFFF Aqueous Film FORMING FOAM |
|
Most suitable for Oil Depots and Refineries
The new family of fire extinguishers contain AFFF which is synthetic foam forming liquid, highly effective on class "B" flammable liquid fires and class "A" solid fires.
WHERE USED
AFFF is widely accepted by all international agencies and fire authorities in most countries. AFFF has proved effective against fuel spill fires, running fuel/spill situation, storage tank fires, running fuel/spill situation, storage tank fires, fuel fires on water, aircraft crash fires and major chemical/solvent fire. AFFF works five times faster than conventional foam.
SPECIFICATIONS
MODEL |
AFFF-SP-45 |
AFFF-150 |
Contents |
Pre-mix Solution of AFFF 45 Litres |
Pre-mix Solution of AFFF 02 150 Litres |
Construction |
Main cylinder of 10 gauge m.s. Sheet, welded. |
|
Pressuring Agent |
Nitrogen Stored Pressure |
CO2 in externally fitted cartridge. |
Duration of Discharge |
60-120 Seconds |
120-180 Seconds |
Operating Pressure |
7 KG/cm2 (nominal) Approx. |
|
Range of Jet |
15-20 meters |
15-20 meters |
Hose Pipe |
10 feet (3m)
(¾" or 18 mm dia ) |
25 feet (7.5 m)
(1 " dia or 25 mm dia) |
Attachments |
Valve with on-off control and discharge nozzle. |
Trolley |
2-wheeled with solid rubber tyres |
Paint |
Red or Cream |
Label |
Non-damaging with instructions for operation. |
|
|
| SODA ACID |
|
For fires on wood, paper, cloth, jute, furnishing and other combustible materials.
SEPCIFICATIONS
 |
Model |
SA-45 |
SA-150 |
Capacity |
45-Litres (10-Gallons) |
150-Litres(34-Gallons) |
Construction |
a) Main body of 10-swg M.S. Sheet, electrically welded, tested to 350 lbs per sq. inch.
b) Cap and other parts of gun-metal.
c) Coated inside with anti-corrosive paints. |
|
Length of Jet |
9-10 meters
(30-35 ft.) |
12-14 meters
(40-45 ft.) |
Duration of Discharge |
2 to 3 minutes |
2 to 4 minutes |
Attachments |
(a). 10 ft x ¾ " ø high Pressure hose.
(b) Open-shut control.
(c) Discharge nozzle. |
(a). 25 ft x 1" ø high Pressure hose.
(b) Open-shut control.
(c) Discharge nozzle. |
Trolley |
Steel tubular frame with rubber tyres of 9 "ø |
Steel tubular frame with rubber tyres of 16" ø |
Operation |
By tilting extinguisher towards ground, allowing solution in both chambers to mix and then opening the wheel-valve. |
|
|
|
| CHEMICAL FOAM |
|
For fires on oils, paints, petrol, varnishes and other highly inflammable liquids.
SPECIFICAITONS
 |
Model |
CF-45 |
CF-150 |
Capacity |
45-Litres (10-Gallons) |
150-Litres (34-Gallons) |
Construction |
(a) Main body of 10-swg M.S. Sheet, Electrically welded, tested to 350 lbs per sq. inch.
(b) Cap and other parts of gun-metal
(c) Coated inside with anti-corrosive paints |
Length of Jet |
9-10 meters (30-35 ft.) |
12-14 meters (40-45 ft.) |
Duration of Discharge |
2 to 3 minutes |
2 to 4 minutes |
Attachments |
a. 10 ft x ¾"ø high Pressure hose.
b. Open-shut control.
c. Discharge nozzle. |
a. 25 ft x 1" ø high Pressure hose.
b. Open-shut control.
c. Discharge nozzle. |
Trolley |
Steel tubular frame with 2 rubber tyres of 9" ø |
Steel tubular frame with 2 rubber tyres of 16" ø |
Operation |
By tilting extinguisher towards ground, allowing solution in both chambers to mix and then opening the wheel-valve. |
|
|
|